Main fuse and load balancing: how much does the charger get?
The car and the charger set an upper limit for charging speed, but the main fuse decides how much of it you actually get while the rest of the house is using power too. Here is what the charger can get with common main fuses, and how load balancing makes it work anyway.
What is the main fuse?
The main fuse (hovedsikring) protects the service cable into the home and decides how much power the whole house can draw at once. It's on the main switch in the fuse box, marked for example "40 A". If you're unsure, the grid company can tell you. Heat pump, water heater, cooker and EV charger all share the same capacity.
How much does the charger get with your main fuse?
Estimates for a charger with load balancing, while the rest of the house is using power. We assume the charger gets about 60 % of the main fuse, at most 32 A. The car and the charger can limit it further.
| Main fuse | To charger | IT 1 phase kW | IT 3 phases kW | TN 3 phases kW |
|---|---|---|---|---|
| 20 A | 12 A | 2.8 | 4.8 | 8.3 |
| 25 A | 15 A | 3.5 | 6 | 10.4 |
| 32 A | 19 A | 4.4 | 7.6 | 13.1 |
| 40 A | 24 A | 5.5 | 9.6 | 16.6 |
| 50 A | 30 A | 6.9 | 12 | 20.7 |
| 63 A | 32 A | 7.4 | 12.7 | 22 |
With a main fuse above 63 A the charger gets the full 32 A. Most cars charge on 1 phase on an IT grid, and take at most 11 kW on a TN grid. If the charger has its own circuit, that applies instead.
At night the house often uses little, and then the charger can get more than the table shows. Enter your main fuse under "My home" at the top of the page, and the whole site will use it. The formulas are in how we calculate.
How load balancing works
Load balancing means the charger always knows how much power the house is using, and turns charging down as it approaches the limit. When the cooker and water heater switch off again, charging goes back up. The car charges a little slower for short periods, but the main fuse doesn't blow.
- Measuring: the charger needs to know the consumption. Some use a separate meter in the fuse box, others read the HAN port on the electricity meter. The HAN port often has to be opened by the grid company first, which you request from them.
- Several chargers: if you have two EVs, or share parking with neighbours, load balancing splits the power between the chargers.
- Ask the electrician whether load balancing is set up and tested, and what your charger needs. It belongs in the quote. See also what affects the cost of the installation.
A charger can't charge below 6 A. If the main fuse is fully used, it pauses until there's room.
Charging and the capacity component of the grid tariff
The Norwegian grid tariff (nettleie) has a capacity component: a fixed monthly amount that depends on how much power you use at most. With most grid companies it's based on the average of the three hours with the highest consumption in the month, on three different days. The higher the peaks, the higher the step.
An EV charger is often the biggest load in the house. Charging at 7.4 kW while the house uses a lot can make that hour a new peak. This keeps the peaks down:
- Charge at night, when the rest of the house uses little. Many chargers and cars can schedule this in the app.
- Lower the max current in the charger's app. At 3.7 kW for 8 hours you get about 130 km, more than most people drive in a day.
- Avoid charging while the cooker, tumble dryer and water heater are all on.
Do you need full speed?
An ordinary day of 33 km needs about 7.3 kWh into the battery, including charging loss. That takes:
- about 59 min at 7.4 kW (1 phase, 32 A)
- about 1 h 58 min at 3.7 kW (1 phase, 16 A)
If you charge at home every night, you'll hardly notice whether the charger gets full power. Full speed matters most if you drive very far every day, or can only charge for a few hours.
When should you upgrade the main fuse?
Rarely just for the EV. It may be worth it if the main fuse already trips often, if you have a small main fuse (25 A or less) and several big loads, or if you'll charge two cars at once. An upgrade must be agreed with the grid company, may need a new service cable and work in the fuse box, and can raise the grid tariff. Try load balancing and scheduled charging first.
1-phase supply
Some cabins and flats only have a 1-phase supply. Then charging is always on 1 phase, whatever the car and charger, and at most 7.4 kW with a 32 A circuit. Choose "1-phase" under "My home", and we'll take that into account.
See what your car gets with each charger in your home